Synchronizers
Disassembly1. Note: Mark parts for assembly. Disassemble the synchronizer.
1. Remove one retaining spring.
2. Flip the synchronizer over and remove the opposite retaining spring.
3. Remove the three insert keys.
4. Remove the sleeve.
2. Inspect all the synchronizer components for wear and damage.
Assembly
1. Note: Match the marked parts for assembly. Assemble the synchronizer.
1. Install the sleeve.
2. Install the insert keys.
3. Install the retaining spring.
4. Flip the synchronizer over and install the opposite retaining spring.