Torque Converter Flushing
Torque Converter Flushing1. CAUTION: The torque converter drain plug and seal are not reusable. If equipped, discard the drain plug and seal, and install a new drain plug and seal assembly.
CAUTION: Mineral spirits used to clean the torque converter must be fresh, non-water based, non-chlorinated and non - halogenated.
Using a suitable torque converter fluid cooler cleaner, flush the torque converter.
2. After flushing, remove the drain plug, if equipped, and drain the remainder of the solvent.
3. Add 1.9 liters (2 quarts) of clean automatic transmission fluid into the torque converter and agitate by hand.
4. Thoroughly drain the solution.
5. If equipped, install a new torque converter drain plug.