Test W
PINPOINT TEST W: THE LH TURN INDICATOR IS NEVER ONTest W1-W2:
Test W3-W4:
Normal Operation
The LH turn indicator bulb is powered through circuit 1393 (LB/RD) when the multifunction switch is placed in the LH turn signal position. The LR turn indicator bulb is grounded through the instrument cluster bulb ground circuit 1205 (BK).
Possible Causes
- circuit 1393 (LB/RD) open
- circuit 1205 (BK) open
- multifunction switch
- instrument cluster