Auxiliary
BLOWER MOTOR - AUXILIARYREMOVAL
1. Remove the LH quarter trim panel.
2. Detach the wire harness.
1 Remove the screws.
2 Disconnect the blower motor electrical connector and position the wire harness aside.
3. Remove the auxiliary blower motor.
1 Detach the vent tube.
2 Remove the screws.
3 Remove the blower motor.
4. Remove the blower motor wheel.
1 Remove the clip.
2 Remove the blower motor wheel.
INSTALLATION
1. To install, reverse the removal procedure.