Test B: DTC B1361 Ignition Run/ACC Circuit Short to Battery
PINPOINT TEST B: DTC B1361 IGNITION RUN/ACC CIRCUIT SHORT TO BATTERYCAUTION: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
Tests B1 - B3:
Test B4:
Normal Operation
The ignition switch receives fused battery voltage from the bussed electrical center (BEC) fuse 64 (20A) circuit 1050 (LG/VT) and fuse 67 (20A) circuit 1118 (RD) The smart junction box (SJB) receives voltage from the ignition switch on circuits 297 (BK/LG), 1044 (WH/YE), 1522 (DG), and 1717 (VT/OG). When placed in the ACC position, the ignition switch provides voltage to the SJB on circuit 297 (BK/LG).
Possible Causes
^ circuit 297 (BK/LG) short to voltage
^ ignition switch
^ SJB