Test E: No Power In Start
PINPOINT TEST E: NO POWER IN STARTCAUTION: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
Tests E1 - E4:
Tests E4 (continued) - E5:
Normal Operation
The ignition switch receives fused battery voltage from the bussed electrical center (BEC) fuse 64 (20A) circuit 1050 (LG/VT) and fuse 67 (20A) circuit 1118 (RD) The smart junction box (SJB) receives voltage from the ignition switch on circuits 297 (BK/LG), 1044 (WH/YE), 1522 (DG), and 1717 (VT/OG). When the ignition switch is placed in the START position, the ignition switch provides voltage to the SJB on circuits 1522 (DG) and 1044 (WH/YE).
Possible Causes
^ circuit 1050 (LG/VT) open
^ circuit 1522 (DG) open
^ circuit 1044 (WH/YE) open
^ ignition switch
^ SJB
^ BEC