Operation CHARM: Car repair manuals for everyone.

Test A: DTC B1365 - Ignition Start Circuit Short to Battery

Pinpoint Test A: DTC B1365 Ignition Start Circuit Short to Battery

Normal Operation
The ignition switch receives fused battery voltage from the bussed electrical center (BEC) fuse 64 (20A) circuit 1050 (LG/VT) and fuse 67 (20A) circuit 1118 (RD). The SJB receives voltage from the ignition switch on circuits 297 (BK/LG), 1044 (WH/YE), 1522 (DG) and 1717 (VT/OG). When placed in the START position, the ignition switch provides voltage to the SJB on circuit 1522 (DG).

Possible Causes
^ Circuit 1522 (DG) short to voltage
^ Ignition switch
^ SJB

A1-A2:




A2-A5: