Operation CHARM: Car repair manuals for everyone.

Test B: DTC B1361 - Ignition Run/ACC Circuit Short to Battery

Pinpoint Test B: DTC B1361 Ignition RUN/ACC Circuit Short to Battery

Normal Operation
The ignition switch receives fused battery voltage from the bussed electrical center (BEC) fuse 64 (20A) circuit 1050 (LG/VT) and fuse 67 (20A) circuit 1118 (RD). The smart junction box (SJB) receives voltage from the ignition switch on circuits 297 (BK/LG), 1044 (WH/YE), 1522 (DG) and 1717 (VT/OG). When placed in the ACC position, the ignition switch provides voltage to the SJB on circuit 297 (BK/LG).

Possible Causes
^ Circuit 297 (BK/LG) short to voltage
^ Ignition switch
^ SJB

B1-B2:




B2-B4: