Test E: The Roof Opening Panel Does Not Open Or Close
PINPOINT TEST E: THE ROOF OPENING PANEL DOES NOT OPEN OR CLOSENormal Operation
The roof opening panel module receives voltage on circuit CBP47 (GN/BU) when the ignition switch is in the ACC or ON position. The roof opening panel module is grounded through circuit GD182 (BK/GY). When the roof opening panel switch is pressed, circuit (BK) and circuit (WH) are connected for open/tilt down or circuit (BK) and circuit (VT) are connected for close/tilt up. The roof opening panel module controls the roof opening panel motor by directing power and ground on circuit (OG) and circuit (RD) to the motor.
This pinpoint test is intended to diagnose the following:
- Circuit breaker
- Wiring, terminals or connectors
- Roof opening panel switch
- Roof opening panel motor
- Roof opening panel module