Evaporator Inlet Line
EVAPORATOR INLET LINERemoval and Installation
NOTE: Installation of a new receiver/drier is not required when repairing the air conditioning system, except when there is physical evidence of contamination from a failed A/C compressor or damage to the receiver/drier.
1. Recover the refrigerant.
2. Remove the evaporator inlet line bracket nut.
- To install, tighten to 8 Nm (71 lb-in).
3. Remove the receiver/drier outlet fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (11 lb-ft).
4. Remove the thermostatic expansion valve (TXV) fitting nut and disconnect the fitting.
- Discard the gasket seals.
- To install, tighten to 15 Nm (11 lb-ft).
5. Remove the evaporator inlet line.
6. To install, reverse the removal procedure.
- Install new gasket seals and O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
7. Evacuate, leak test and charge the refrigerant system.