Expansion Valve: Service and Repair
THERMOSTATIC EXPANSION VALVERemoval and Installation
NOTE: An in-line filter is installed in the auxiliary evaporator inlet line at the floorpan bracket connection. A restriction in this filter may cause misdiagnosis of a failed thermostatic expansion valve (TXV). This filter must be inspected before a new TXV is installed.
1. Recover the refrigerant.
2. Remove the D-pillar trim panel. Service and Repair
3. Detach the rear portion of the LH quarter trim panel and position away from the TXV.
4. Remove the 4 clips and the TXV cover.
5. Remove the insulating tape.
- Retain the tape for reuse.
6. Remove the temperature sensing bulb clip and detach the temperature sensing bulb from the evaporator outlet line.
7. Disconnect the 2 TXV fittings and remove the TXV.
- Discard the O-ring seals.
- To install, tighten to 23 Nm (17 lb-ft).
8. To install, reverse the removal procedure.
- Install new O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil.
9. Evacuate, leak test and charge the refrigerant system.