Operation CHARM: Car repair manuals for everyone.

Vacuum Check Valve






Apply 54 kPa (16 in. Hg.) vacuum to "check" side of valve and trap. If vacuum remains above 50.6 kPa (15 in. Hg.) for 10 seconds, the valve is acceptable.