Blower Motor - Intermittent/Inoperative
89ford04
AIR CONDITIONING - ELECTRONIC AUTOMATIC TEMPERATURE CONTROL (EATC) - BLOWER MOTOR INOPERATIVE
Article No. 89-6-7
FORD: 1988-89 TAURUS
LINCOLN-MERCURY: 1988-89 CONTINENTAL, SABLE
ISSUE: An inoperative blower motor or a blower motor that operates intermittently may be caused by the climate control assembly, blower motor, blower motor controller or high blower relay malfunction.
ACTION: Check the climate control assembly and blower motor for proper operation by following the diagnostic procedures in the appropriate Car Shop Manual. If either component is faulty, replace it and operate the system to make sure it functions okay. If the climate control assembly and the blower motor are okay, replace both the blower motor controller and high blower relay.
NOTE: DO NOT JUST REPLACE ONE COMPONENT AT A TIME IF SERVICE TO THE BLOWER MOTOR CONTROLLER OR HIGH BLOWER RELAY IS REQUIRED. BOTH THE BLOWER MOTOR CONTROLLER AND THE HIGH SPEED BLOWER RELAY MUST BE REPLACED AT THE SAME TIME.
PART NUMBER PART NAME CLASS
E6DZ-19E624-A Blower Motor Controller B
E6DZ-19E703-A Relay C
NOTE: Parts Have Been Bombined, New Part # E9DZ-19E624-A
OTHER APPLICABLE ARTICLES: None
WARRANTY STATUS: Eligible Under Basic Warranty Coverage
OPERATION DESCRIPTION TIME
890607A Install Controller & 1.0 Hr.
Relay-Continental
890607A Install Controller & 0.8 Hr.
Relay-Taurus/Sable
DEALER CODING
BASIC PART NO. CONDITION CODE
19E624 09
OASIS CODES: 2600, 2610, 2611, 2630, 2632