Installation
1. Carefully position pointer parallel to rectangular raised portion of dial.CAUTION: The gauges are calibrated at the factory. Excessively rough handling could disturb the calibration.
2. Guide the pointer carefully through slot in main dial. Then, position gauge on mounting bosses and install mounting screws. Tighten screws to 0.8-1.4 Nm (7-12 b-in).
3. On column shift vehicles, install transmission selector indicator.
4. Install main dial assembly to cluster backplate by aligning it on guides. Press carefully and firmly to seat all electrical terminals.
NOTE: Lower flood lamp bulb filters are not secured and may fall out.
5. On vehicles with tachometer cluster, install two lower flood lamp bulb and socket assemblies.
6. Position mask-and-lens assembly and install eight mask-and-lens retaining screws.
7. On vehicles with tachometer cluster, install lower trim panel.