A16
A16 VAPS Harness And Connector Check (Diagnostic Connector)
- Turn ignition switch to OFF.
- Doors and hood must be closed for proper readings.
- Disconnect VAPS harness connector from module.
- Connect DVOM as shown.
- Measure resistance between Circuit 606 of VAPS harness connector and Circuit 606 of diagnostic connector.
Typical resistance is 2.0 Ohms or less.
- Measure voltage between Circuit 606 of VAPS harness connector and Circuit 606 of diagnostic connector.
Typical voltage is less than 0.1 volt.
- Move leads to Circuit 200.
Measure resistance between Circuit 200 of VAPS harness connector and Circuit 200 of diagnostic connectors.
Typical resistance is 2.0 Ohms or less.
- Measure voltage between Circuit 200 of VAPS harness connector and Circuit 200 of diagnostic connector.
Typical voltage is less than 0.1 volt.
Are resistance and voltage near given values?
Yes
Go to A2. A1 - A3
No
SERVICE harness.
Go to A2.