Operation CHARM: Car repair manuals for everyone.

Blower Motor: Service and Repair

1. Disconnect battery ground cable.
2. Open glove compartment door, then release retainers and allow glove box door to swing downward.

Fig. 11 Blower Motor Removal:





3. Remove recirculation duct support bracket to cowl attaching screw, then the recirculation door motor vacuum connection. Remove six recirculation duct to heater case attaching screws, then guide duct from between instrument panel and heater case and remove.
4. Disconnect blower motor electrical connection.
5. Remove blower wheel attaching clip and blower wheel.
6. Remove blower motor attaching bolts, then the blower motor from evaporator case.
7. Reverse procedure to install.