X89 - Check Power to Pump Circuit Continuity
- Key "OFF".
- Low Speed Fuel Pump (LFP) relay disconnected.
- Disconnect Constant Control Relay Module (CCRM).
Resistance Test Points:
- Measure resistance between Pin 5 of the CCRM vehicle harness connector and the power-to-pump circuit at the LFP relay vehicle harness connector.
- Is resistance less than 10.0 ohms?
Yes -- Replace LFP relay. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)
No -- Verify condition of Fuel Pump Dropping Resistor (about 1 ohm resistance). If OK, service open in power-to-pump circuit between LFP relay and splice to "common" power-to-pump circuit. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)