Operation CHARM: Car repair manuals for everyone.

Blower Motor: Service and Repair


1. Disconnect battery ground cable.
2. Remove screws securing right ventilator control cable to instrument panel.
3. Remove screw securing right register duct to lower right edge of instrument panel.

Fig. 10 Vent Assembly Removal:





4. Remove glove box, then pull right register duct from installed position between air inlet duct and right register opening, Fig. 7.
5. Remove ventilator grille from bottom of ventilator assembly, then screws securing right ventilator assembly to blower housing.

Fig. 8 Blower motor removal:





6. Remove hub clamp spring from blower wheel hub, Fig. 8.
7. Pull blower wheel from blower shaft, then remove three blower motor flange attaching screws.
8. Pull blower motor from housing, disconnect electrical connector, then remove motor from vehicle.