Fuel Delivery and Air Induction: Testing and Inspection
WARNING: Before servicing or replacing any components in the fuel system, reduce the possibility of injury or fire, refer to Service Precautions.- Key Off.
- Before releasing fuel system pressure at the schrader fitting, observe Service Precautions to avoid fuel spillage and injury.
- Install the fuel pressure tester.
- Enter Output Test Mode and run the fuel pump to obtain maximum fuel pressure.
- Verify that the observed fuel pressure is within specified limits.
Specifications 240-280 kPa (35.0-40.0 PSI)