Quick Test 2.0 - Setup
Connect Rotunda New Generation Star (NGS) Tester 418-FO48 (007-00500) or equivalent to Data Link Connector (DLC).The following are procedures to run OBD II procedures.
VEHICLE AND TESTER PREPARATION
Prepare the vehicle as follows:
- Place transmission range selector lever in PARK.
- Run engine to operating temperature.
- Apply parking brake.
- Block wheels.
- Turn off all electrical loads including A/C and defroster. (if A/C is ON, DTC P 1460 will set.)
Prepare the NGS as follows:
- Turn ignition switch to the OFF position.
- Verify that the proper PROGRAM card is inserted in the NGS.
- Connect J 1962/16 way Data Communication Link (DCL) cable adapter to the NGS.
- Connect NGS DCL cable adapter securely into the vehicle's data link connector.
- Connect the NGS power supply cable to the vehicle battery power supply through cigar lighter or at the battery with alligator clip adapter.
- Turn the ignition switch to the RUN position, or start vehicle if necessary.
- The NGS is now ready to communicate with the PCM.
NOTE: Do not replace parts based on a code, perform Pinpoint Tests first.