Initial Inspection and Diagnostic Overview
1. Verify the customer's concern by operating the active restraint system to duplicate the condition.2. Inspect to determine if one of the following mechanical or electrical concerns apply:
Mechanical
^ Inspect safety belt webbing for integrity.
Electrical
^ Open fuse.
^ Bare, broken or disconnected wire.
^ connector not tightly engaged.
^ Safety belt warning indicator lamp burned out or broken.
3. If the inspection reveals obvious concern(s) that can be readily identified, service as required.
4. If the concern(s) remains after the inspection, determine the symptom(s) and go to the Symptom Chart. Symptom Related Diagnostic Procedures