Flow of Diagnosis
1. Verify the customer's concern by operating speed control system to duplicate the condition.2. Inspect to determine if one of the following mechanical or electrical concerns apply:
VISUAL INSPECTION CHART
Mechanical
Inspect and verify that:
- Actuator cable is adjusted properly without holding the throttle open or increasing idle speed.
- Throttle linkage operates freely and smoothly when connected to the actuator cable and speed control servo.
Electrical
- Verify proper horn operation
- Verify stoplamp operation
- check circuit fuses:
Fuse Junction Panel
^ Fuse 28 (15A)
^ Fuse 6 (15A)
- Speed Control Indicator Bulb
- Inspect and verify that:
^ Connections are complete with no loose wires or terminals.
^ Wiring is not broken, shorted or corroded.
^ Wiring is not misrouted.
3. If inspection reveals obvious concern(s) that can be readily identified, repair as required.
4. Perform the Self-Test Diagnostics. Reading and Clearing Diagnostic Trouble Codes