Compressor HVAC: Service Precautions
CAUTION:- If installing a new air conditioning compressor due to an internal failure of the old unit, you must carry out the following procedures to remove contamination from the air conditioning system.
- If A/C flushing equipment is available, carry out the flushing of the air conditioning system prior to installing a new air conditioning compressor.
- If A/C flushing equipment is not available, carry out filtering of the air conditioning system after a new air conditioning compressor has been installed.
- Install a new evaporator core orifice as directed by the A/C flushing or filtering procedure.
- Install a new suction accumulator as directed by the A/C flushing or filtering procedure.
- To prevent refrigerant system contamination, do not allow dirt or other foreign materials to enter the A/C compressor.