Principles of Operation
PRINCIPLES OF OPERATIONThe smart junction box (SJB) monitors the headlamp switch position by sending multiple voltage reference signals to the headlamp switch. When the headlamp switch is in any given position, that input signal is routed to ground.
The SJB also monitors the multifunction switch for a flash-to-pass or high beam request. There are 2 voltage reference circuits which monitor this. When the multifunction switch is in the FLASH-TO-PASS or HIGH BEAM position, the voltage signal is routed to ground.
NOTE: The flash-to-pass feature does not require any input from the headlamp switch.
When the SJB receives an input requesting the headlamps on, the SJB supplies voltage to the low beam and high beam bulbs as necessary.