Starter Motor - CVT
STARTER MOTOR - CVTRemoval and Installation
WARNING: When carrying out maintenance on the starting system, be aware that the heavy gauge leads are connected directly to the battery. Make sure the protective caps are in place when maintenance is completed.
1. Disconnect the battery ground cable.
2. Remove the air cleaner assembly.
3. Remove the starter solenoid terminal cover.
4. Remove the nuts and position the starter solenoid cables aside.
- To install, tighten the large nut to 12 Nm (9 lb-ft).
- To install, tighten the small nut to 6 Nm (53 lb-in).
5. Remove the bolts and the starter motor.
- To install, tighten to 25 Nm (18 lb-ft).
6. To install, reverse the removal procedure.