Air Cleaner
Air Cleaner
Removal and Installation
1. Disconnect the Mass Air Flow (MAF) sensor electrical connector.
2. Loosen the clamp and disconnect the Air Cleaner (ACL) outlet pipe from the ACL.
- To install, tighten to 5 Nm (44 lb-in).
3. Remove the 2 bolts from the ACL assembly.
- To install, tighten to 5 Nm (44 lb-in).
4. Separate the 2 ACL feet from the rubber grommets and remove the ACL assembly.
5. NOTE: Make sure that the 2 ACL feet are seated into the rubber grommets under the ACL assembly.
NOTE: The ACL outlet pipe should be securely sealed to prevent unmetered air from entering the engine.
To install, reverse the removal procedure.