Expansion Valve: Service and Repair
Thermostatic Expansion Valve
Underbody Line Connections
Thermostatic Expansion Valve (TXV) Connections
Removal and Installation
1. Recover the refrigerant. Service and Repair
2. Remove the 4 cross vehicle beam nuts and remove the beam.
- To install, tighten to 30 Nm (22 lb-ft).
3. Remove the auxiliary evaporator outlet and inlet line fitting nuts and position the auxiliary lines aside (if equipped).
- Discard the O-ring seals and gasket seals.
- To install, tighten to 15 Nm (133 lb-in).
4. Remove the Thermostatic Expansion Valve (TXV) fitting nut.
- Discard the O-ring seals.
- To install, tighten to 8 Nm (71 lb-in).
5. Remove the 2 TXV bolts.
- To install, tighten to 8 Nm (71 lb-in).
6. Remove the TXV.
- Discard the O-ring seals.
7. To install, reverse the removal procedure.
- Install new O-ring seals and gasket seals.
- Add the correct amount of clean PAG oil. Service and Repair
8. Evacuate, leak test and charge the refrigerant system. Service and Repair Component Tests and General Diagnostics