Alternator: Service and Repair
Generator - 3.0L
Removal and Installation
1. Remove the A/C compressor.
2. Disconnect the battery. For additional information, refer to Battery.
3. Position the generator protective cover aside, remove the nut and position the generator B+ terminal aside.
- To install, tighten to 12 Nm (106 lb-in).
4. Disconnect the generator electrical connector.
5. Remove the 3 bolts and the generator.
- To install, tighten to 47 Nm (35 lb-ft).
6. To install, reverse the removal procedure.