Operation CHARM: Car repair manuals for everyone.

Pinpoint Test P: The Hazard Lamps Are Inoperative/Always On




Turn Signal and Hazard Lamps

Pinpoint Tests

Pinpoint Test P: The Hazard Lamps Are Inoperative/Always On

Refer to Wiring Diagram Set 90 (Fusion/Milan/MKZ, Fusion Hybrid/Milan Hybrid), Turn Signal/Stop/Hazard Lamps for schematic and connector information. Diagrams By Number

Normal Operation

The Smart Junction Box (SJB) sends a voltage signal to the hazard flasher lamp switch. When the hazard flasher lamp switch is pressed, the voltage signal is routed to ground. When the SJB detects a request for the hazard lamps, the SJB provides voltage to the appropriate turn lamps.

The hazard flasher lamp switch is a momentary contact switch.

The hazard flasher lamp switch for MKZ is integrated into the Front Controls Interface Module (FCIM).

- DTC B2071 (Hazard Switch Signal Short to Ground) - an on-demand DTC that sets when the SJB detects a short to ground from the hazard flasher lamp switch input circuit.

This pinpoint test is intended to diagnose the following:

- Wiring, terminals or connectors
- Hazard flasher lamp switch (Fusion/Milan)
- FCIM (MKZ)
- SJB



PINPOINT TEST P: THE HAZARD LAMPS ARE INOPERATIVE/ALWAYS ON

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.

-------------------------------------------------
P1 CHECK THE RECORDED DTCs FROM THE SJB SELF-TEST


- Check the recorded DTCs from the SJB self-test.
- Is DTC B2071 present?

Yes
GO to P2.

No
GO to P4.

-------------------------------------------------
P2 CHECK THE HAZARD FLASHER LAMP SWITCH


- Disconnect: Hazard Flasher Lamp Switch C2039 (Fusion/Milan).
- Disconnect: FCIM C2402 (MKZ).
- Ignition ON.
- Enter the following diagnostic mode on the scan tool: SJB Self-Test.
- Repeat the SJB self-test.
- Is DTC B2071 still present?

Yes
GO to P3.

No
For Fusion or Milan, INSTALL a new hazard flasher lamp switch. REFER to Hazard Flasher Lamp Switch Service and Repair. TEST the system for normal operation.

For MKZ, INSTALL a new FCIM. REFER to Accessories and Optional Equipment TEST the system for normal operation.

-------------------------------------------------
P3 CHECK THE HAZARD LAMP REQUEST INPUT CIRCUIT FOR A SHORT TO GROUND


- Ignition OFF.
- Disconnect: SJB C2280b.
- For Fusion or Milan, measure the resistance between the hazard flasher lamp switch C2039-6, circuit CLS32 (BN/YE), harness side and ground.




- For MKZ, measure the resistance between the FCIM C2402-6, circuit CLS32 (BN/YE), harness side and ground.




- Is the resistance greater than 10,000 ohms?

Yes
GO to P7.

No
REPAIR circuit CLS32 (BN/YE) for a short to ground. CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
P4 CHECK FOR A VOLTAGE SIGNAL TO THE HAZARD FLASHER LAMP SWITCH OR THE FCIM


- Ignition OFF.
- Disconnect: Hazard Flasher Lamp Switch C2039 (Fusion/Milan).
- Disconnect: FCIM C2402 (MKZ).
- For Fusion or Milan, measure the voltage between the hazard flasher lamp switch C2039-6, circuit CLS32 (BN/YE), harness side and ground.




- For MKZ, measure the voltage between the FCIM C2402-6, circuit CLS32 (BN/YE), harness side and ground.




- Is the voltage greater than 10 volts?

Yes
For Fusion or Milan, GO to P6.

For MKZ, INSTALL a new FCIM. REFER to Accessories and Optional Equipment. TEST the system for normal operation.

No
GO to P5.

-------------------------------------------------
P5 CHECK THE HAZARD LAMP REQUEST INPUT CIRCUIT FOR AN OPEN


- For Fusion or Milan, measure the resistance between the SJB C2280b-48, circuit CLS32 (BN/YE), harness side and the hazard flasher lamp switch C2039-6, circuit CLS32 (BN/YE), harness side.




- For Fusion or Milan, measure the resistance between the SJB C2280b-48, circuit CLS32 (BN/YE), harness side and the FCIM C2402-6, circuit CLS32 (BN/YE), harness side.




- Is the resistance less than 5 ohms?

Yes
GO to P7.

No
REPAIR circuit CLS32 (BN/YE) for an open. TEST the system for normal operation.

-------------------------------------------------
P6 CHECK FOR VOLTAGE TO THE HAZARD FLASHER LAMP SWITCH USING THE CONNECTOR GROUND


- Measure the voltage between the hazard flasher lamp switch C2039-6, circuit CLS32 (BN/YE), harness side and the hazard lamp switch C2039-2, circuit GD116 (BK/VT), harness side.




- Is the voltage greater than 10 volts?

Yes
INSTALL a new hazard flasher lamp switch. REFER to Hazard Flasher Lamp Switch Service and Repair. TEST the system for normal operation.

No
REPAIR circuit GD116 (BK/VT) for an open. TEST the system for normal operation.

-------------------------------------------------
P7 CHECK FOR CORRECT SJB OPERATION


- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?

Yes
INSTALL a new SJB. REFER to Body Control Systems. TEST the system for normal operation.

No
The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------