Compressor To Condenser Discharge Line
Compressor to Condenser Discharge Line
Removal and Installation
1. Recover the refrigerant. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.
2. Remove the condenser inlet fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (133 lb-in).
3. Disconnect the A/C pressure transducer electrical connector.
4. Remove the compressor discharge fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (133 lb-in).
5. Remove the compressor-to-condenser discharge line.
6. To install, reverse the removal procedure.
- Install new gasket seals and O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to Climate Control System - General Information and Diagnostics Refrigerant Oil Adding.
7. Evacuate, leak test and charge the refrigerant system. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.