Suction Accumulator To Compressor Line
Suction Accumulator to Compressor Line
Removal and Installation
1. Recover the refrigerant. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.
2. Disconnect the suction accumulator outlet fitting.
- Discard the O-ring seals.
3. Remove the compressor suction fitting nut and disconnect the fitting.
- Discard the O-ring seal and gasket seal.
- To install, tighten to 15 Nm (133 lb-in).
4. Remove the suction accumulator-to-compressor line.
5. To install, reverse the removal procedure.
- Install a new gasket seal and O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to Climate Control System - General Information and Diagnostics Refrigerant Oil Adding.
6. Evacuate, leak test and charge the refrigerant system. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.