Suction Accumulator To Evaporator Line
Suction Accumulator To Evaporator Line
Removal and Installation
1. Recover the refrigerant. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.
2. Disconnect the suction accumulator inlet fitting.
- Discard the O-ring seals.
3. Disconnect the evaporator core outlet fitting.
- Discard the O-ring seals.
4. Remove the suction accumulator-to-evaporator line.
5. To install, reverse the removal procedure.
- Install new O-ring seals.
- Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to Climate Control System - General Information and Diagnostics Refrigerant Oil Adding.
6. Evacuate, leak test and charge the refrigerant system. For additional information, refer to Climate Control System - General Information and Diagnostics Air Conditioning (A/C) System Recovery, Evacuation and Charging.