A/C - Does Not Blow Cold Air
SI M 64 02 04Heating and Air Conditioning
August 2004
Service Engineering
SUBJECT
A/C Does Not Blow Cold Air
MODEL
R50 (Cooper) with CVT.
SITUATION
The A/C line from the condenser to the evaporator is cut by a sharp edge on the CVT oil pan.
CORRECTION
1. In order that an effective solution can be introduced in series production, your help is required when this problem is identified. Before disturbing the routing of the cut hose, take digital pictures from the angles as shown, and attach them to a PuMA case.
2. Replace the hose and reposition it so that it does not rub on the oil pan. Refer to Repair Instruction RA64 50 009 (Drawing off, evacuating and filling A/C system - R134a).