Instrument Cluster Test Functions
JUJ0902FB-001621101
1. Requesting the reset function for the instrument cluster of the MINI
IMPORTANT: read through once beforehand!!
A. Ignition lock in position "2" (ignition on)
B. Press the trip recorder reset button for 5 seconds
C. Press the trip recorder reset button again immediately until "tESt 19." appears in the display.
D. Wait a little - "_L_off" and "_L_on" appear alternately in the display
E. With "_L_off" press the trip recorder reset button once
F. Press the trip recorder reset button again immediately until "tESt 21." appears
G. Wait until "21.0" appears in the display
Press the trip recorder reset button once -> Reset is started.
2. Test function for instrument cluster
2.1 To start the test functions, the trip distance reset button in the instrument cluster must be pressed for 5 seconds. �tESt 1� appears in the display. Pressing the reset button again takes you to the different test numbers.
2.2 In the case of locked tests (tests 3 to 21), with test 19 on appearance of the display "_L_oFF" (alternates between _L_oFF and _L_oN) pressing the reset button opens the lock. Then the display then jumps to test 0 so that the corresponding test number group can be selected immediately by pressing again.
2.3 If a test number contains other subfunctions, after choice of the test number the display "tESt x.0" (x stands for the selected test number) appears automatically in the display. Pressing the reset button again enables selection of another subtest step (function) or one can be started as with "system test".