Removal and Replacement
64 52 ... Instructions For Opening And Part Replacement In Refrigerant Circuit
WARNING:
- Avoid contact with refrigerant and refrigerant fluid
- Follow safety information for handling R134a refrigerant
- Follow safety information for handling refrigerant fluid
IMPORTANT:
- Always use new O-rings each time A/C connections are opened (refer to Electronic Parts Catalogue)
They must not be coated.
Use special tool 00 9 030 to install sealing rings without damaging them.
- Open the refrigerant circuit for as short of a period as possible.
- Close all components and lines in the refrigerant circuit and return parts immediately following the removals at openings with special tool 32 1 270 to prevent penetration of moisture or foreign objects.
- If the refrigerant circuit was closed at the openings with special tool 32 1 270 but it remains open for more than 24 hours, the dryer insert for the air conditioning must be replaced.
I. Part replacement as preliminary work fur further repair work and based on gradual leakage.
(minor leak, e.g. hairline crack)
Procedure:
- Draw off heating and air conditioning system, then determine drawn-off amount of refrigerant
- Carry out part replacement
- Replace removed refrigerant fluid and additionally top up with new refrigerant fluid according to components replaced:
- Compressor: refer to Notes on compressor replacement
- Evaporator: 10 ml
- Capacitor: 20 ml
- Desiccant insert/dryer flask: 20 ml
- Each replaced refrigerant line: 10 ml
- Capacitor with integrated dryer: 40 ml
- Safety pressure switch and seals: no additional refrigerant fluid
- Evacuate and fill A/C system
II. Part replacement due to sudden leak
(major leak, e.g. pipe break due to accident)
Procedure:
- Draw off heating and air conditioning system, then determine drawn-off amount of refrigerant
- Carry out part replacement
- Replace removed refrigerant fluid and additionally replace with new refrigerant fluid according to parts replaced:
- Compressor: refer to Notes on compressor replacement
- Evaporator: 35 ml
- Capacitor: 35 ml
- Desiccant insert/dryer flask: 55 ml
- Each replaced refrigerant line: 35 ml
- Capacitor with integrated dryer: 55 ml
- Safety pressure switch and seals: no additional refrigerant fluid
- Evacuate and fill A/C system