P0030
2A63 - P0030Information saved in
DME
Fault code
2A63 - P0030
Fault text
Oxygen sensor heating before catalytic converter, activation
Fault description
Pre-catalyst oxygen sensor heater, activation
Condition for fault identification
Test condition:
Output stage diagnosis
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
0.5 sec.
Action in service
Check wiring harness between oxygen sensor and DME
Replace oxygen sensor
Replace DME
Fault effect and breakdown warning
It is possible to continue driving. Because the oxygen sensor
cannot be used for closed-loop control the exhaust emissions
will exceed the official limits.
MIL lights up
Higher exhaust emissions
Increased fuel consumption
Surge
Driver information
Warning light:
MIL ON
Service instruction
None