Operation CHARM: Car repair manuals for everyone.

Pinout Values and Diagnostic Parameters

TERMINAL VOLTAGE CHECK CHART
1. Measure the voltages between terminals (32) and (34) (ground terminals) and each respective terminal.

Part 1 Of 2:




Part 2 Of 2:





2. The terminal layouts are shown in the illustrations below.

NOTE: Do not measure terminal voltage for approximately three seconds after the ignition switch is turned on. The ABS-ECU performs the initial check during that period.

RESISTANCE AND CONTINUITY BETWEEN HARNESS-SIDE CONNECTOR TERMINALS
1. Turn the ignition switch off and disconnect the ABS-ECU connectors before checking resistance and continuity.
2. Check between the terminals indicated in the table below.





3. The terminal layouts are shown in the illustration below.