Operation CHARM: Car repair manuals for everyone.

Symptom Related Diagnostic Procedures

TROUBLESHOOTING HINTS
Charging warning light dose not go on when the ignition switch is turned to ON, before the engine starts.
- Check the bulb.

Charging warning light dose not switch off after the engine starts.
- Check the IC voltage regulator inside the generator. Discharged or overcharged battery.
- Check the IC voltage regulator inside the generator. The charging warning light illuminates dimly.
- Check the diode (inside the combination meter) for a short-circuit.

TROUBLESHOOTING GUIDE
The charging system troubleshooting guide is shown in the following steps.

STEP 1.

Q: Check the battery.

OK: Go to Step 2.

NG: Charge or replace the battery

STEP 2.

Q: Check the generator drive belt.

OK: Go to Step 3.

NG: Adjust the belt tension or replace the belt.

STEP 3.

Q: Does the charging warning light shine brightly when the ignition switch is turned on?

YES: Go to Step 4.

NO:
- Check the ignition switch.
- Check for burned-out charging warning light.
- Check the generator.
- Check the charging warning light-related circuits.

STEP 4.

Q: Does the charging warning light go out after starting the engine?

YES: Go to Step 5.

NO: Check the generator.

STEP 5.

Q: Is an oscilloscope available?

YES: Go to Step 6.

NO: Go to Step 7.

STEP 6.

Q: Check by using the oscilloscope.

OK: Go to Step 7.

NG: Check the generator.

STEP 7.
- Engine: 2,500 r/min
- Headlight: ON (high beam)
- Voltage between generator terminal B and the positive battery terminal

OK: 0.5 V or less

- Voltage between the negative battery terminal and generator body

OK: 0.5 V or less

Q: Check the generator output line and ground line.

OK: Go to Step 8.

NG: Check the generator output line and ground line

STEP 8.

Q: Perform the output current test.

OK: Go to Step 9.

NG: Check the generator.

STEP 9.

Q: Perform the Regulated voltage test.

OK: Go to Step 10.

NG: Check the generator.

STEP 10.

Q: Test for voltage drops on the generator output line.

OK: Generator is normal. Check other systems.

NG: Check the output line