05 - Inspection Procedure
Blower Fan and Motor do not Stop Operating.DIAGNOSIS
STEP 1. Check the harness wires between the blower switch connector C-07, blower resistor connector C-22, and the blower fan motor connector C-21.
Q: Are the harness wires between the blower fan and motor switch connector C-07, blower resistor connector C-22, and the blower fan motor connector C-21 in good condition?
YES: Go to Step 2.
NO: Repair it. Then go to Step 4.
STEP 2. Check the blower relay continuity.
Q: Is there continuity at the blower relay?
YES: Go to Step 3.
NO: Replace. Then go to Step 4.
STEP 3. Check the blower switch continuity.
Q: Is there continuity at the blower switch?
YES: Go to Step 4.
NO: Replace. Then go to Step 4.
STEP 4. Check symptoms.
Q: Does the blower motor stop operating?
YES: This diagnosis is complete. (If no malfunctions are not found in all steps, an intermittent malfunction is suspected. Refer to How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction.)
NO: Go to Step 1.