Operation CHARM: Car repair manuals for everyone.

Service Specifications

REGULATED VOLTAGE V
Ambient temp.
at Regulator Standard value

-20°C (-4°F) 14.2-15.4 Volts

20°C (68°F) 13.9-14.9 Volts

60°C (140°F) 13.4-14.6 Volts

80°C (176°F) 13.1-14.5 Volts


ROTOR COIL RESISTANCE Approx. 3 - 5

OUTPUT CURRENT LIMIT 70% of nominal output current