Injector Connector
ForewordConnectors which are loose shall be rectified by removing the female terminal from connector housing and raising its lance to establish a more secure engagement. Removal of connector terminal used for MFI and ELC-4 A/T control circuit shall be done in the following manner.
Injector Connector (Part 1 Of 2):
1. Remove waterproof cap.
Injector Connector (Part 2 Of 2):
2. Insert tip of screwdriver [1.4 mm (0.06 in.) width] into connector in a manner as shown in the figure, press in terminal lance and pull out harness.
3. Press contact point of male terminal down by holding a screwdriver [1.4 mm (0.06 in.) width] in a manner as shown in the figure.
CAUTION: Make sure that lance is in proper condition before terminal is inserted into connector.