Normal Scan Data Values
Item No 11 - 18:
Item No 21 - 29:
Item No 41 - 87:
Item No 88 - 95:
NORMAL SCAN DATA VALUES
NOTE:
*1: In a new vehicle [driven approximately 500 km (311 mile) or less], the volume air flow sensor output frequency is sometimes 10% higher than the standard frequency.
*2: If the idle speed is lower than the standard value on a very cold engine (approximately -20°C (-4°F) even when the IAC motor is fully opened, the air volume limiter built in the throttle body could be defective.
*3: The injector drive time represents the time when the cranking speed is at 250 r/min or below when the power supply voltage is 11 volts.
*4: In a new vehicle [driven approximately 500 km (311 mile) or less], the injector drive time is sometimes 10% longer than the standard time.