Fuel Pump: Testing and Inspection
Fuel Pump Connector:
1. Disconnect the fuel pump connector (located on the R.H. frame rail, near the spring perch).
2. Using an ohm meter, check for continuity between terminals d and e.
a. If continuity does not exist, replace the fuel pump and re-test.
b. If continuity does exist, proceed to step 3.
3. Perform FUEL PRESSURE TEST.