Air Flow Meter/Sensor: Specifications
OUTPUT VOLTAGE: [1]Terminal A to ground, engine idling with no load 1.0-1.7 Volts DC
Terminal A to ground, as engine is revved up to 3.0 Volts DC
Supply Voltage 12 Volts DC
[1] Engine fully warmed up, Mass Air Flow Sensor (MAF) terminal connected.