Displaying & Reading Trouble Codes
DIAGNOSIS FUNCTION- Odo/trip meter segment can be checked in diagnosis mode.
- Meters/gauges can be checked in diagnosis mode.
HOW TO ALTERNATE DIAGNOSIS MODE
1. Turn ignition switch to ON and change odo/trip meter to "TRIP A" or "TRIP B".
2. Turn ignition switch to OFF.
3. Turn ignition switch to ON when pushing odo/trip meter switch.
4. Push odo/trip meter switch 1 second.
5. Release odo/trip meter switch.
6. Push odo/trip meter switch more than three times within 7 seconds.
7. All odo/trip meter segments should be turned on.
NOTE: If some segments are not turned on, unified meter control unit with odo/trip meter should be replaced.
At this point, the unified control meter is turned to diagnosis mode.
8. Push odo/trip meter switch. Indication of each meter/gauge should be as shown left during pushing odo/trip meter switch if it is no malfunctioning.
NOTE: It takes about a few seconds for indication of fuel gauge and water temperature gauge to become stable.