Diagnostic Procedure 2
Inspecting SRS malfunctioning parts by using CONSULT-II - Diagnosis mode1. Turn ignition switch OFF.
2. Connect CONSULT-II to data link connector.
3. Turn ignition switch ON.
4. Touch "START".
5. Touch "AIR BAG".
6. Touch "SELF-DIAG [CURRENT]".
7. Self-diagnosis result is displayed on "SELF-DIAG [CURRENT]".
If no malfunction is detected on "SELF-DIAG [CURRENT]" but malfunction is indicated by the "AIR BAG" warning lamp in User mode, go to "DIAGNOSTIC PROCEDURE 4" for diagnosing the following cases:
- Self-diagnosis result (previously stored in the memory) might not have been erased after repair.
- The SRS system malfunctions intermittently.
8. Touch "PRINT".
9. Compare diagnostic codes to "CONSULT-II Diagnostic Code Chart".
10. Touch "BACK" key of CONSULT-II until "SELECT SYSTEM" appears in order to return to User mode from Diagnosis mode, then turn off CONSULT-II.
11. Turn ignition switch OFF, then turn off and disconnect CONSULT-II and disconnect both battery cables.
12. Repair the system as outlined by the Repair order in CONSULT-II Diagnostic Code Chart that corresponds to the self-diagnosis result. For replacement procedure of component parts, refer to "REMOVAL AND INSTALLATION".
13. After repairing the system, go to "DIAGNOSTIC PROCEDURE 3", for final checking.