Diagnostic Procedure 5
Inspecting SRS intermittent malfunction by using CONSULT-II-Diagnosis mode1. Turn ignition switch OFF.
2. Connect CONSULT-II to data link connector.
3. Turn ignition switch ON.
4. Touch "START".
5. Touch "AIR BAG".
6. Touch "SELF-DIAG [PAST)".
7. If self-diagnosis result is displayed on "SELF-DIAG [PAST]", go to step 10.
If no malfunction is detected on "SELF-DIAG [PAST]", touch "BACK" and go back to "SELECT DIAG MODE".
8. Touch "TROUBLE DIAG RECORD".
NOTE: With "TROUBLE DIAG RECORD", self-diagnosis results previously erased by a reset operation can be displayed.
9. Self-diagnosis result is displayed on "TROUBLE DIAG RECORD".
10. Touch "PRINT".
11. Compare self-diagnosis result to "Intermittent Malfunction Diagnostic Code Chart".
12. Touch "BACK" key of CONSULT-II until "SELECT SYSTEM" appears, then turn off CONSULT-II.
13. Turn ignition switch OFF then turn off and disconnect CONSULT-II and disconnect both battery cables.
14. Repair the system as outlined by the Repair order that corresponds to the self-diagnosis result in "Intermittent Malfunction Diagnostic Code Chart". For replacement procedure of component parts, refer to "REMOVAL AND INSTALLATION".
15. Go to "DIAGNOSTIC PROCEDURE 3", for final checking.