Diagnostic Procedure 2
DIAGNOSTIC PROCEDURE 2 / With CONSULT-II Scan ToolInspecting SRS malfunctioning parts by using CONSULT-II - Diagnosis mode
1. Turn ignition switch OFF".
2. Connect CONSULT-II to data link connector.
3. Turn ignition switch "ON".
4. Touch "START".
5. Touch "AIR BAG".
6. Touch "SELF-DIAG [CURRENT]".
7. Diagnostic codes are displayed on "SELF-DIAG [CURRENT]".
If no malfunction is detected on "SELF-DIAG [CURRENT]" even though malfunction is detected in "SRS Operation Check", check the battery voltage.
If the battery voltage is less than 9 V, charge the battery. Then go to DIAGNOSTIC PROCEDURE 3".
Diagnostic Procedure 3
If the battery voltage is OK, refer to DIAGNOSTIC PROCEDURE 4 (CONTINUE FROM DIAGNOSTIC PROCEDURE 2)", to diagnose the following cases:
Diagnostic Procedure 4
- Self-diagnostic result SELF-DIAG [PAST]" (previously stored in the memory) might not be erased after repair.
- The SRS system malfunctions intermittently.
8. Touch "COPY".
9. Compare diagnostic codes to CONSULT-II Diagnostic Code Chart". Refer to "CONSULT-II Diagnostic Code Chart ('SELF-DIAG [CURRENT]')".
10. Touch BACK" key of CONSULT-II until "SELECT SYSTEM" appears in order to return to User mode from Diagnosis mode.
11. Turn ignition switch "OFF", then turn off and disconnect CONSULT-II, and disconnect both battery cables.
12. Repair the system as outlined by the Repair order" in CONSULT-II Diagnostic Code Chart", that corresponds to the self- diagnostic result. For replacement procedure of component parts, refer to the applicable Removal and Installation procedure.
13. After repairing the system, refer to "DIAGNOSTIC PROCEDURE 3", for final checking.
Diagnostic Procedure 3