Power Door Lock
System DescriptionPower is supplied at all times
- through 40 A fusible link (letter f, located in the fuse and fusible link box)
- to circuit breaker terminal (+)
- through circuit breaker terminal (-)
- to smart entrance control unit terminal 51.
Power is supplied at all times
- through 7.5 A fuse [No. 28, located in the fuse block (J/B)]
- to smart entrance control unit terminal 49, and
- to key switch terminal 1.
Ground is supplied
- to smart entrance control unit terminals 43 and 64
- through body grounds M14 and M68.
INPUT
With the key in the ignition key cylinder, power is supplied
- through key switch terminal 2
- to smart entrance control unit terminal 25.
With front door LH open, ground is supplied
- to smart entrance control unit terminal 1
- through front door switch LH terminal 2
- through front door switch LH terminal 3
- through body grounds B6 and B10.
With front door RH open, ground is supplied
- to smart entrance control unit terminal 2
- through front door switch RH terminal (+).
With the key inserted in the front door key cylinder switch LH and turned to LOCK, ground is supplied
- to smart entrance control unit terminal 11
- through front door key cylinder switch LH terminal 1
- through front door key cylinder switch LH terminal 2
- through body grounds M14 and M68.
With the key inserted in the back door key cylinder switch and turned to LOCK, ground is supplied
- to smart entrance control unit terminal 11
- through back door key cylinder switch terminal 1
- through back door key cylinder switch terminal 2
- through body grounds D402 and D404.
With the key inserted in the front door key cylinder switch LH and turned to UNLOCK, ground is supplied
- to smart entrance control unit terminal 10
- through front door key cylinder switch LH terminal 3
- through front door key cylinder switch LH terminal 2
- through body grounds M14 and M68.
With the key inserted in the back door key cylinder switch and turned to UNLOCK, ground is supplied
- to smart entrance control unit terminal 10
- through back door key cylinder switch terminal 3
- through back door key cylinder switch terminal 2
- through body grounds D402 and D404.
With the main power window and door lock/unlock switch pressed to LOCK, ground is supplied
- to smart entrance control unit terminal 5
- through main power window and door lock/unlock switch terminal 15
- through main power window and door lock/unlock switch terminal 10
- through body grounds M14 and M68.
With the door lock/unlock switch RH pressed to LOCK, ground is supplied
- to smart entrance control unit terminal 5
- through door lock/unlock switch RH terminal 6
- through door lock/unlock switch RH terminal 4
- through body grounds M14 and M68.
With the main power window and door lock/unlock switch pressed to UNLOCK, ground is supplied
- to smart entrance control unit terminal 4
- through main power window and door lock/unlock switch terminal 11
- through main power window and door lock/unlock switch terminal 10
- through body grounds M14 and M68.
With the door lock/unlock switch RH pressed to UNLOCK, ground is supplied
- to smart entrance control unit terminal 4
- through door lock/unlock switch RH terminal 3
- through door lock/unlock switch RH terminal 4
- through body grounds M14 and M68.
OUTPUT
Unlock
Ground is supplied
- to front door lock actuator LH terminal 4
- to front door lock actuator RH terminal 4
- to rear door lock actuator LH terminal 4
- to rear door lock actuator RH terminal 4 and
- to back door lock actuator terminal 1
- through smart entrance control unit terminal 54.
FRONT DOOR LH
Power is supplied
- to front door lock actuator LH terminal 2
- through smart entrance control unit terminal 55.
FRONT DOOR RH
Power is supplied
- to front door lock actuator RH terminal 2
- through smart entrance control unit terminal 56.
REAR DOOR LH
Power is supplied
- to rear door lock actuator LH terminal 2
- through smart entrance control unit terminal 56.
REAR DOOR RH
Power is supplied
- to rear door lock actuator RH terminal 2
- through smart entrance control unit terminal 56.
BACK DOOR
Power is supplied
- to back door lock actuator terminal 3
- through smart entrance control unit terminal 56.
Then, the doors are unlocked.
Lock
Ground is supplied
- to front door lock actuator LH terminal 2
- through smart entrance control unit terminal 55 and
- to front door lock actuator RH terminal 2
- to rear door lock actuator LH terminal 2
- to rear door lock actuator RH terminal 2 and
- to back door lock actuator 3
- through smart entrance control unit terminal 56.
Power is supplied
- to front door lock actuator LH terminal 4
- to front door lock actuator RH terminal 4
- to rear door lock actuator LH terminal 4
- to rear door lock actuator RH terminal 4 and
- to back door lock terminal 1
- through smart entrance control unit terminal 54.
Then, the doors are locked.
OPERATION
- The main power window and door lock/unlock switch and the door lock/unlock switch RH can lock and unlock all doors.
- With the key inserted in the front door key cylinder LH or the back door key cylinder, turning it to LOCK locks all doors; turning it to UNLOCK once unlocks the corresponding door; turning it to UNLOCK again within 5 seconds of the first unlock operation unlocks all other doors (signal from door key cylinder switch).
Key Reminder
When performing a door locking operation using either the main power window and door lock/unlock switch, the door lock/unlock switch RH, the front door LH lock knob or a multi-remote controller, all the doors will lock and then will immediately unlock if the
- key switch is in INSERTED position (key is inserted into ignition key cylinder) and
- ignition switch is in the OFF position and
- either front door switch LH or RH is in OPEN position (door is open).