Sensor Reference Graphs In Data Monitor Mode
The following are the major sensor reference graphs in "DATA MONITOR" mode. (Select "MANU TRIG" in "DATA MONITOR" with CONSULT-II. "Trigger Point" is set to 100%, "Recording Speed" is set to MAX..)THRTL POS SEN, ABSOL TH.P/S, CLSD THL P05
The data for "THRTL POS SEN", "ABSOL TH.P/S" and "CLSD THL P05" when depressing the accelerator pedal with the ignition switch ON.
The signal of "THRTL POS SEN" and "ABSOL TH.P/S" should rise gradually without any intermittent drop or rise after "CLSD THL P05" is changed from "ON" to "OFF".
ENG SPEED, MAS A/F SE-B1, THRTL P05 SEN, H02S2 (B1), HO2S1 (B1), INJ PULSE-B1
The data for "ENG SPEED", "MAS A/F SE-B1", "THRTL POS SEN", "HO2S2 (B1)", "HO2S1 (B1)" and "INJ PULSE-B1" when reviving engine quickly up to 4,800 rpm under no load after warming up engine to normal operating temperature.
Each value is for reference, the exact value may vary.